Sterility Testing Islator

 

Model            

GSI-4G-CN

GSI-4G-1PTC-CN

GSI-8G-1PTC-CN

Description 

Single-sided operation with one main operation chamber

Single-sided operation with one Pass-through Chamber + one main operation chamber

Double-sided operation  with one Pass-through Chamber + one main operation chamber

Decontamination

VHP / Dry FOG

Control System

Siemens PLC+IPC / 21 CFR PART 11 / GAMP5

Options

 Intelligent Bacterial Collector / Wireless Glove Leak Tester /  RTP / IP Camera / Particle Counter / Microbial Sampler / CD/CV etc.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Product Description

The built-in VHP sterilization system in the Sterility Test Isolator employs a novel rapid VHP sterilization technology, which effectively penetrates HEPA filters and achieves a log6 microbial reduction with biological indicators, without any form of condensation occurring. The Sterility Test Isolator undergoes leak detecting in strict accordance with international standards, achieving ≤0.5% Vol/hr. With excellent integration capabilities, it utilizes a Siemens PLC control system for fully automated intelligent control, ensuring stable and reliable operation of all integrated components. It can integrate environmental monitoring equipment such as particle counters and microbial samplers. The graphical human-machine interface offers storage, electronic export, or printing of sterilization data and environmental monitoring reports based on customer requirements. The control system design complies with GAMP5 guidelines and meets the requirements of 21 CFR Part 11 for electronic records, electronic signatures, and audit trail. CD/CV services are available to optimize sterilization parameters and shorten sterilization cycles while ensuring sterilization effectiveness, helping users save validation costs and time based on actual processes. Mock-up validation is also offered, allowing customers to simulate the ergonomic rationality of the isolator on-site.

Technical Parameters

Model

GSI-4G-CN

GSI-4G-1PTC-CN

GSI-8G-1PTC-CN

Description

Single-sided operation with one main operation chamber

Single-sided operation with one Pass-through Chamber + one main operation chamber

Double-sided operation  with one Pass-through Chamber + one main operation chamber

Overall Size  

1800mm*900mm*2500mm

2800mm*900mm*2500mm

2800mm*1240mm*2500mm

Main Operation Chamber

1760mm*650mm*680mm

1960mm*650mm*680mm

1800mm*1200mm*680mm

Pass-through Chamber

760mm*550mm*680mm

670mm*650mm*680mm

Gloves

4

4

8

Decontamination

VHP / Dry FOG

Control System

Siemens PLC+IPC / 21 CFR PART 11 / GAMP5

Internal Metallic Surface Finish

SS 316L≥3mm /  Ra≤0.5µm

External Metallic Surface Finish

SS 304≥1.5-2mm /  Ra≤1.0µm

Options

Intelligent Bacterial Collector / Wireless Glove Leak Tester / RTP / IP Camera / Particle Counter / Microbial Sampler / CD / CV etc.